MEASUREMENT RANGE
SpO2: 1% to 100%
Pulse rate: 20 to 250 beats per minute (bpm)
Pulse amplitude: 0.03% to 20%
ACCURACY
Saturation: (% SpO2 ± 1 SD)
Adult: 70% to 100% ± 2 digits
Neonate: 70% to 100% ± 3 digits
Low perfusion: 70% to 100% ± 2 digits
Pulse rate: 20 to 250 bpm ± 3 digits
Low perfusion: 20 to 250 bpm ± 3 digits
Electrical
INSTRUMENT
Power requirements: 100 to 240 VAC, 50/60Hz, 45 VA
Fuse rating: Fast-acting 2A 32VAC/DC, fast-acting 500mA 32VAC/50DC
BATTERY
Type: Lithium ion
Battery capacity: Minimum of five hours using new, fully charged battery with no alarms
Environmental
OPERATING TEMPERATURE
Instrument: 5°C to 40°C (41°F to 104°F)
Transport/storage temperature (in shipping carton): -20°C to 60°C (-4°F to 140°F)
OPERATING HUMIDITY
15% to 93% noncondensing
OPERATING ALTITUDE
-170 m to 4877 m (-557 ft to 16,000 ft)
Physical Characteristics

WEIGHT
1.6 kg (3.5 lbs)
SIZE
82 H x 255 W x 165 D (mm)
(3.23 H x 10.04 W x 6.50 D (in))
Equipment Compliance
STANDARDS COMPLIANCE
EN ISO 9919: 2009, EN ISO 80601-2-61:2011
EN IEC 60601-1: 2005
EN IEC 60601-1-2: 2nd edition
EN IEC 60601-1:1998 + A1:1991 + A2:1995
EN 60601-1:1990 + A11:1993 + A12:1993 + A13:1996
CAN/CSA C22.2 No. 601.1 M90
UL 60601-1: 1st edition
Equipment Classifications
Type of protection against electric shock: Class 1 (internally powered)
Degree of protection against electric shock: Type BF – applied part
Mode of operation: Continuous
Electromagnetic compatibility: IEC 60601-1-2:2007
Liquid ingress: IPX2
Degree of safety: Not suitable for use in the presence of flammable anesthetics
Output
Trend data download
Nurse call capability
Display/Indicators
Pulse: Amplitude indicator (eight segments)
Visual indicators: Pulse search, audible alarms silenced or off, interference indicator, battery charging, SatSeconds alarm management clock, pleth
Alarms
Audible and visual alarms for high/low saturation and pulse rate
SatSeconds alarm management settings: 10, 25, 50 and 100, or off
Audible and visual warning indicators for low battery and sensor off
Audible and visual sensor disconnect alarms